-40%

AC energy/power meter with free 40A/60A/80A/120A transformer /temperature sensor

$ 41.71

Availability: 92 in stock
  • Display Type: LCD
  • Operating Frequency: 50/60 Hz
  • Meter Type: Electronic
  • Brand: Digital
  • Condition: New
  • Mounting Style: Wall Mounting
  • Model: EPM 6700
  • MPN: ZHURUI
  • Number of Phases: 1
  • Nominal Voltage Rating: 220 V
  • Tariff: Single
  • Meter Accuracy: Class 0.5
  • Actual Voltage Rating: AC85V~265V
  • Actual Current Rating: 40/60/80/100/120
  • Custom Bundle: No
  • Country/Region of Manufacture: China
  • Features: Digital Meters

    Description

    Packing list
    1.EPM6700
    Electrical Parameter Tester
    -----------------------------------------------------------------------------------------------------------1pcs
    2.Current Transformer-------------------------------------------------------------------------------------------------------------------------------------------- 1pcs
    3.Temperature Sensor ---------------------------------------------------------------------------------------------------------------------------------------------1pcs
    4.Screws---------------------------------------------------------------------------------------------------------------------------------------------------------------2pcs
    5.User Manual-----------------------------------------------------------------------------------------------------------------------------------------------------1copy
    6.Warranty card ------------------------------------------------------------------------------------------------------------------------------------------------1
    paper
    7.Product certification-----------------------------------------------------------------------------------------------------------------------------------------1paper
    Product Features
    EPM6700 Electrical Parameter tester has 2.8-inch TFT LCD, touch-key, it integrates the power, power factor, voltage, current, electric energy, frequency, temperature and cumulative time measurement functions, and has the upper and lower limit alarm function, so that you can get the multi-purpose practical and convenient.
    Key Features

    l
    Digital operate and control;
    l
    2.8-inch TFT color LCD display;
    l
    The power resolution can be switched automatically. When the power <1000W, it has one decimal, the unit is W; When the power <10kW, it has 3 decimals; the unit is KW; When the power >10kW, it has 2 decimals, the unit is KW;
    l
    Can select to measure Temperature or Frequency, they are alternative;
    l
    Temperature degrees Celsius and Fahrenheit are alternative;
    l
    Can select the total time (from the meter was open, can be cleared) or working time (accumulated time when the power greater than 0, can be cleared)
    l
    Voltage, current, power , and temperature can be set to alarm of Upper and Lower limit,

    if exceed , it will be sound to alarm ;
    l
    Press’
    O
    ’, the accumulated time, working time and total electricity are cleared together;
    l
    Energy-saving setting: you can set that the screen will be closed without any action in 1minute, 5 minutes, or 10 minutes, or the screen can be set not to be closed. Even if the screen was closed, which not influence the monitor’s measuring. If any button is touched, the screen will be opened again;
    l
    Over range Indication;
    l
    Mounting box type 86 is used, thickness is 36.5mm;
    l
    It supports 1000:1 or 2000:1 current transformer, the max current of the transformer is 120A;
    Technical Index
    Electrical Parameters
    Parameter
    Measure scope
    resolution
    Measure accuracy
    Voltage
    AC85~265V
    [1]
    0.1V
    ±
    (0.5FS+0.5V)
    1000:1

    40A Transformer
    Power
    0.5W~10kW
    [2]
    0.1W
    [3]
    ±
    (0.5FS+0.5W)
    [3]
    Current
    0.01~40A
    [1]
    0.001A
    ±
    (0.5FS+0.003A)
    1000:1

    60A
    Transformer
    Power
    0.5w~15kW
    [2]
    0.1w
    [3]
    ±
    (0.5FS+0.5W)
    [3]
    Current
    0.01~60A
    [1]
    0.001A
    ±
    (0.5FS+0.003A)
    1000:1

    80A
    Transformer
    Power
    1w~20kW
    [2]
    0.1w
    [3]
    ±
    (0.5FS+1W)
    [3]
    Current
    0.02~80A
    [1]
    0.001A
    ±
    (0.5FS+0.005A)
    2000:1

    100A
    Transformer
    Power
    1w~25kW
    [2]
    0.1w
    [3]
    ±
    (0.5FS+1W)
    [3]
    Current
    0.02~100A
    [1]
    0.001A
    ±
    (0.5FS+0.005A)
    2000:1

    120A
    Transformer
    Power
    1w~30kW
    [2]
    0.1w
    [3]
    ±
    (0.5FS+1W)
    [3]
    Current
    0.02~120A
    [1]
    0.001A
    ±
    (0.5FS+0.005A)
    Power factor
    0~1.000
    0.001
    ±
    (0.5FS+0.005)
    Frequency
    45~65Hz
    0.1Hz
    ±
    (0.5FS+0.1Hz)
    Electricity
    0~999999kWh
    0.0001kWh
    [5]
    ±
    (0.5FS+0.0001kWh)
    [5]
    Temperature
    -10

    ~110

    0.1

    ±
    (0.5FS+0.1

    )
    Note:
    [1].
    Voltage and Current are True RMS value.
    [2].
    Power is active power.
    [3].
    When the power <1000W, the resolution is 0.1W, when the power >=1kW, the resolution is 0.001kW, when the power >10kW, the resolution is 0.01kW
    [4].
    The resolution of energy is auto adjusted by the measuring result, the maximum resolution is 0.0001.
    [5]. For 120A current transformer, only ratio of 2000:1 is supported.
    Timing Index
    Timing range
    999 days 23 hours 59 minutes
    Timing resolution
    1 minute
    Supported current transformer
    Ratio
    1000:1
    2000:1
    Max Current
    40A
    60A
    80A
    100A
    120A
    40A
    60A
    80A
    100A
    120A
    Supported




    ×





    Other indexes
    Working voltage
    AC85~265V
    Working frequency
    50~60Hz
    Working temperature
    0~40

    Working humidity

    90%RH
    Dimension (L x W x H)
    86mmx86mmx36.5mm
    Weight
    EPM6700’s look
    Considerations
    1.
    The machine cannot work in hot and humid environment, please use it in normal temperature and humidity.
    2.
    The working voltage of the machine is AC85V~AC265V.
    3.
    The working current cannot be greater than the maximum current of current transformer.
    4.
    The current transformer cannot be open circuit, otherwise it will output high voltage, which will cause safety problems.
    5.
    Do not let the machine expose to the dust, corrosive gases or other harmful substances in the environment when use and keep.
    6.
    Must power-off operation be carried out during installation, and live operation is prohibited to avoid electric shock.
    7.
    If the machine failed working, don not open the machine and replace parts by yourself to avoid electric shock, please contact the manufacturer.